1.
Molecules ; 29(9)2024 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-38731560

RESUMO

2, 6-diisopropylaniline (2, 6-DIPA) is a crucial non-intentionally organic additive that allows the assessment of the production processes, formulation qualities, and performance variations in biodegradable mulching film. Moreover, its release into the environment may have certain effects on human health. Hence, this study developed simultaneous heating hydrolysis-extraction and amine switchable hydrophilic solvent vortex-assisted homogeneous liquid-liquid microextraction for the gas chromatography-mass spectrometry analysis of the 2, 6-DIPA additive and its corresponding isocyanates in poly(butylene adipate-co-terephthalate) (PBAT) biodegradable agricultural mulching films. The heating hydrolysis-extraction conditions and factors influencing the efficiency of homogeneous liquid-liquid microextraction, such as the type and volume of amine, homogeneous-phase and phase separation transition pH, and extraction time were investigated and optimized. The optimum heating hydrolysis-extraction conditions were found to be a H2SO4 concentration of 2.5 M, heating temperature of 87.8 °C, and hydrolysis-extraction time of 3.0 h. As a switchable hydrophilic solvent, dipropylamine does not require a dispersant. Vortex assistance is helpful to speed up the extraction. Under the optimum experimental conditions, this method exhibits a better linearity (0.0144~7.200 µg mL-1 with R = 0.9986), low limit of detection and quantification (0.0033 µg g-1 and 0.0103 µg g-1), high extraction recovery (92.5~105.4%), desirable intra- and inter-day precision (relative standard deviation less than 4.1% and 4.7%), and high enrichment factor (90.9). Finally, this method was successfully applied to detect the content of the additive 2, 6-DIPA in PBAT biodegradable agricultural mulching films, thus facilitating production process monitoring or safety assessments.


Assuntos
Aminas , Compostos de Anilina , Cromatografia Gasosa-Espectrometria de Massas , Interações Hidrofóbicas e Hidrofílicas , Microextração em Fase Líquida , Solventes , Microextração em Fase Líquida/métodos , Cromatografia Gasosa-Espectrometria de Massas/métodos , Solventes/química , Aminas/química , Aminas/análise , Compostos de Anilina/química , Hidrólise , Poliésteres/química
2.
Anal Chim Acta ; 1307: 342620, 2024 Jun 08.
Artigo em Inglês | MEDLINE | ID: mdl-38719413

RESUMO

BACKGROUND: Pharmacokinetic studies are pivotal in drug development, focusing on absorption, distribution, and excretion of active compounds. Effective sample preparation methods play a crucial role in these studies. Traditional techniques like protein precipitation and liquid-liquid extraction often involve toxic solvents and are time-consuming. Recently, deep eutectic solvent (DES) has emerged as an eco-friendly alternative due to its high efficiency, low cost, and low toxicity. This study introduces a novel sample pretreatment method using CO2-switchable DES in liquid-liquid microextraction (LLME) to enhance speed, accuracy, and sensitivity in complex biological samples analysis. RESULTS: A liquid-liquid microextraction sample pretreatment method based on switchable DES combined with high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) was established for the analysis of urine and tissue samples. The method was optimized through systematic investigation of key parameters, including DES type, volume, molar ratio, pH, vortex time, gas purge time, and salt addition. The resulting procedure exhibited satisfying linearity (r2 ≥ 0.9958), good precision (RSD ≤6.01 %), desirable recovery (52.44%-98.12 %) and matrix effect (86.22%-119.30 %), and the accuracy and precision of stability were within the ±15 % limit. The proven methods were further applied to urinary excretion study and tissue distribution study of Nelumbinis plumula (NP) extract. The results indicated that the total cumulative excretion of liensinine, isoliensinine and neferine in urine within 240 h was 4.96 %, 0.66 % and 0.44 %, respectively. The tissue distribution study showed that alkaloids mainly distribute in liver, kidney, and spleen. SIGNIFICANCE: This research introduces a groundbreaking technique distinguished by its simplicity, speed, cost-effectiveness, and environmental friendliness. This approach, utilizing CO2-switchable DES as an extraction solvent for LLME, integrates deproteinization and removal of interfering molecules into a single step. This integration showcases its efficiency and convenience, demonstrating significant promise for various applications in the analysis of biological samples. Additionally, this study provides the first report on urinary excretion and tissue distribution of alkaloids from NP using a DES-LLME method. These findings offer valuable insights into the in vivo behavior of herbal medicine, enhancing understanding of pharmacological actions and facilitating clinical rational administration.


Assuntos
Dióxido de Carbono , Solventes Eutéticos Profundos , Microextração em Fase Líquida , Espectrometria de Massas em Tandem , Microextração em Fase Líquida/métodos , Dióxido de Carbono/química , Solventes Eutéticos Profundos/química , Animais , Distribuição Tecidual , Espectrometria de Massas em Tandem/métodos , Cromatografia Líquida de Alta Pressão , Masculino , Ratos , Ratos Sprague-Dawley
3.
J Chromatogr A ; 1722: 464852, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38581974

RESUMO

Xiangdan Injection are commonly used traditional Chinese medicine formulations for the clinical treatment of cardiovascular diseases. However, the trace components of Dalbergia odorifera in Xiangdan Injection pose a challenge for evaluating its quality due to the difficulty of detection. This study proposes a technology combining dispersive liquid-liquid microextraction and back-extraction (DLLME-BE) along with Bar-Form-Diagram (BFD) to address this issue. The proposed combination method involves vortex-mixing tetradecane, which has a lower density than water, with the sample solution to facilitate the transfer of the target components. Subsequently, a new vortex-assisted liquid-liquid extraction step is performed to enrich the components of Dalbergia odorifera in acetonitrile. The sample analysis was performed on HPLC-DAD, and a clear overview of the chemical composition was obtained by integrating spectral and chromatographic information using BFD. The combination of BFD and CRITIC-TOPSIS strategies was used to optimize the process parameters of DLLME-BE. The determined optimal sample pre-treatment process parameters were as follows: 200 µL extraction solvent, 60 s extraction time, 50 µL back-extraction solvent, and 90 s back-extraction time. Based on the above strategy, a total of 29 trace components, including trans-nerolidol, were detected in the Xiangdan Injection. This combination technology provides valuable guidance for the enrichment analysis of trace components in traditional Chinese medicines.


Assuntos
Dalbergia , Medicamentos de Ervas Chinesas , Microextração em Fase Líquida , Microextração em Fase Líquida/métodos , Cromatografia Líquida de Alta Pressão/métodos , Medicamentos de Ervas Chinesas/química , Medicamentos de Ervas Chinesas/análise , Dalbergia/química , Limite de Detecção , Acetonitrilas/química , Reprodutibilidade dos Testes
4.
Environ Monit Assess ; 196(5): 454, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38622372

RESUMO

This work presents a sensitive and accurate analytical method for the determination of phenytoin at trace levels in domestic wastewater and synthetic urine samples by gas chromatography-mass spectrometry (GC-MS) after the metal sieve-linked double syringe liquid-phase microextraction (MSLDS-LPME) method. A metal sieve was produced in our laboratory in order to disperse water-immiscible extraction solvents into aqueous media. Univariate optimization studies for the selection of proper extraction solvent, extraction solvent volume, mixing cycle, and initial sample volume were carried out. Under the optimum MSLDS-LPME conditions, mass-based dynamic range, limit of quantitation (LOQ), limit of detection (LOD), and percent relative standard deviation (%RSD) for the lowest concentration in calibration plot were figured out to be 100.5-10964.2 µg kg-1, 150.6 µg kg-1, 45.2 µg kg-1, and 9.4%, respectively. Detection power was improved as 187.7-folds by the developed MSLDS-LPME-GC-MS system while enhancement in calibration sensitivity was recorded as 188.0-folds. In the final step of this study, the accuracy and applicability of the proposed system were tested by matrix matching calibration strategy. Percent recovery results for domestic wastewater and synthetic urine samples were calculated as 95.6-110.3% and 91.7-106.6%, respectively. These results proved the accuracy and applicability of the proposed preconcentration method, and the obtained analytical results showed the efficiency of the lab-made metal sieve apparatus.


Assuntos
Microextração em Fase Líquida , Poluentes Químicos da Água , Cromatografia Gasosa-Espectrometria de Massas/métodos , Águas Residuárias , Fenitoína/análise , Poluentes Químicos da Água/análise , Monitoramento Ambiental/métodos , Solventes/química , Água/análise , Microextração em Fase Líquida/métodos , Limite de Detecção
5.
Environ Monit Assess ; 196(5): 485, 2024 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-38684572

RESUMO

Herein, we aimed to develop a new environmentally friendly liquid-liquid microextraction (LLME) method based on hydrophobic deep eutectic solvent (hDES) synthesized using biodegradable dl-menthol and decanoic acid for the spectrophotometric determination of toxic basic fuchsin dye in environmental water samples. The parameters affecting the extraction efficiency such as pH, mole ratio, and volume of hDES (1:2) and type and volume of organic solvent, sample volume, times of vortex, ultrasonic bath and centrifuge, ionic strength, and matrix effect were investigated and optimized. Under optimal conditions, the calibration curve showed linearity in the range of 7.4-167 µg L-1 with a coefficient of determination of 0.9994. The limit of detection, intra-day and inter-day precision, and recovery values were 2.25 µg L-1, 2.46% and 4.45%, and 105 ± 3%, respectively. The preconcentration and enrichment factors were found to be 30 and 61.5, respectively. The proposed hDES-LLME methodology was successfully applied to the environmental water samples to detect toxic BF dye (95-105%). Finally, the ecological impact of the suggested method was evaluated using the analytical eco-scale (PPS:88), complementary green analytical procedure indexe (ComplexGAPI), and the Analytical GREEnness tool (0.63). The assessment results showed that the presented analytical method can be regarded as a green LLME approach for the determination of the BF in water.


Assuntos
Microextração em Fase Líquida , Mentol , Poluentes Químicos da Água , Microextração em Fase Líquida/métodos , Poluentes Químicos da Água/análise , Poluentes Químicos da Água/química , Mentol/química , Solventes Eutéticos Profundos/química , Interações Hidrofóbicas e Hidrofílicas , Química Verde/métodos , Corantes/química , Monitoramento Ambiental/métodos
6.
Talanta ; 274: 126038, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38579419

RESUMO

Herein, a High-Throughput Semi-automated Emulsive Liquid-Liquid Microextraction (HTSA-ELLME) method was developed to detect Succinate Dehydrogenase Inhibitor (SDHI) fungicides in food samples via UHPLC-MS/MS. The Oil-in-Water (O/W) emulsion comprising a hydrophobic extractant and water was dilutable with the aqueous sample solution. Upon injecting the primary emulsion into the sample solution, a secondary O/W emulsion was formed, allowing SDHI fungicides to be extracted. Subsequently, a NaCl-saturated solution was injected in the secondary O/W emulsion as a demulsifier to rapidly separate the extractant, eliminating the need for centrifugation. A 12-channel electronic micropipette was used to achieve a high-throughput semi-automation of the novel sample pretreatment. The linear range was 0.003-0.3 µg L-1 with R2 > 0.998. The limit of detection was 0.001 µg L-1. The HTSA-ELLME method successfully detected SDHI fungicides in water, juice, and alcoholic beverage samples, with recoveries and relative standard deviations of 82.6-106.9% and 0.8-5.8%, respectively. Unlike previously reported liquid-liquid microextraction approaches, the HTSA-ELLME method is the first to be both high-throughput and semi-automated and may aid in designing pesticide pretreatment processes in food samples.


Assuntos
Bebidas Alcoólicas , Sucos de Frutas e Vegetais , Fungicidas Industriais , Microextração em Fase Líquida , Espectrometria de Massas em Tandem , Microextração em Fase Líquida/métodos , Espectrometria de Massas em Tandem/métodos , Cromatografia Líquida de Alta Pressão/métodos , Fungicidas Industriais/análise , Sucos de Frutas e Vegetais/análise , Bebidas Alcoólicas/análise , Emulsões/química , Água/química , Contaminação de Alimentos/análise , Automação
7.
Anal Methods ; 16(18): 2938-2947, 2024 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-38668806

RESUMO

The nature and proportions of hydrocarbons in the cuticle of insects are characteristic of the species and age. Chemical analysis of cuticular hydrocarbons allows species discrimination, which is of great interest in the forensic field, where insects play a crucial role in estimating the minimum post-mortem interval. The objective of this work was the differentiation of Diptera order insects through their saturated cuticular hydrocarbon compositions (SCHCs). For this, specimens fixed in 70 : 30 ethanol : water, as recommended by the European Association for Forensic Entomology, were submitted to solid-liquid extraction followed by dispersive liquid-liquid microextraction, providing preconcentration factors up to 76 for the SCHCs. The final organic extract was analysed by gas chromatography coupled with flame ionization detection (GC-FID), and GC coupled with mass spectrometry was applied to confirm the identity of the SCHCs. The analysed samples contained linear alkanes with the number of carbon atoms in the C9-C15 and C18-C36 ranges with concentrations between 0.1 and 125 ng g-1. Chrysomya albiceps (in its larval stage) showed the highest number of analytes detected, with 21 compounds, while Lucilia sericata and Calliphora vicina the lowest, with only 3 alkanes. Non-supervised principal component analysis and supervised orthogonal partial least squares discriminant analysis were performed and an optimal model to differentiate specimens according to their species was obtained. In addition, statistically significant differences were observed in the concentrations of certain SCHCs within the same species depending on the stage of development or the growth pattern of the insect.


Assuntos
Dípteros , Cromatografia Gasosa-Espectrometria de Massas , Hidrocarbonetos , Animais , Hidrocarbonetos/análise , Dípteros/química , Cromatografia Gasosa-Espectrometria de Massas/métodos , Microextração em Fase Líquida/métodos , Entomologia Forense/métodos , Análise de Componente Principal , Análise Discriminante
8.
Artigo em Inglês | MEDLINE | ID: mdl-38564965

RESUMO

In the present work, a new microextraction procedure combined with gas chromatography-mass spectrometry has been developed for the analysis of several aliphatic amines from urine sample. The sample preparation method was a continuous homogenous liquid phase microextraction that was based on in-situ preparation of 4-chlorophenol: choline chloride deep eutectic solvent. The deep eutectic solvent was prepared by passing the mixture of related compounds through a syringe barrel filled with exothermic salts (calcium chloride and potassium bromide). The released heat by dissolving the salts and increasing the solution ionic strength assists the formation of the deep eutectic solvent. The influence of various factors on the efficiency of the proposed procedure including salts amount, flow rate, pH, salting-out effect, and extraction solvent volume was studied. The calibration curves were linear broadly over the concentration range of 1.2-250 ng mL-1 with coefficient of determinations ≥0.996. The enrichment factors were in the range of 188-246 and the limits of detection and quantification were 0.16-0.37 and 0.56-1.2 ng mL-1, respectively. Based on the results, the offered method was sensitive, rapid, eco-friendly, and efficient for extracting and determining aliphatic amines in urine samples.


Assuntos
Microextração em Fase Líquida , Solventes/química , Microextração em Fase Líquida/métodos , Cromatografia Gasosa-Espectrometria de Massas/métodos , Solventes Eutéticos Profundos , Sais , Colina , Limite de Detecção
9.
Anal Methods ; 16(16): 2585-2596, 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38606467

RESUMO

Excessive dietary polyamines (PAs), including putrescine (PUT), spermine (SPM), and spermidine (SPD), have become a worldwide concern due to their carcinogenicity and reduced shelf life. A modern miniaturized on-chip electromembrane extraction (EME) has been applied to extract these compounds from chicken breast samples. This method is based fundamentally on ionic compounds' electrostatic attraction, diffusion, and solubility in the acceptor phase. The chemical structure of polyamines enables their efficient extraction using an electric driving force on a microchip device. HCl solution (0.1 mol L-1) was applied as an aqueous acceptor solvent. Dispersive liquid-liquid microextraction was performed after EME to facilitate joining three-phase EME to GC-MS and improve the merit figures. The total ranges of 3.77-7.89 µg g-1, 3.48-7.02 µg g-1, and 0.78-2.20 µg g-1 were acquired as PUT, SPM and SPD concentrations in chicken breast, respectively. The results demonstrate that the level of PAs in fresh chicken breast samples is not concerning, but it may reduce the quality of chicken meat over time. This novel analytical technique has several advantages: high recovery, substantial quickness, remarkable selectivity, and good enrichment factors. This emerging method could be generalized to other studies to analyze different foodstuffs.


Assuntos
Galinhas , Cromatografia Gasosa-Espectrometria de Massas , Microextração em Fase Líquida , Poliaminas , Animais , Microextração em Fase Líquida/métodos , Cromatografia Gasosa-Espectrometria de Massas/métodos , Poliaminas/química , Poliaminas/análise , Dispositivos Lab-On-A-Chip , Carne/análise , Membranas Artificiais
10.
Anal Chim Acta ; 1301: 342387, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38553114

RESUMO

BACKGROUND: Parallel artificial liquid membrane extraction (PALME) is a 96-well plate setup variant of liquid-phase microextraction. Basic or acidic analytes are extracted in neutral form from the sample, through a supported liquid membrane (SLM), and into aqueous acceptor. PALME is already considered a green extraction technique, but in the current conceptual work, we sought to make it even greener by replacing the use of organic solvents with essential oils (EO). PALME was combined with LC-MS/MS for analysis of plasma samples and multiple drugs of abuse with toxicological relevance (amphetamines, phenethylamines, synthetic cathinones, designer benzodiazepines, ayahuasca alkaloids, lysergic acid diethylamide, and ketamine). RESULTS: Fourteen EO were compared to organic solvents frequently used in PALME. The EO termed smart & sassy yielded the best analyte recovery for all drugs studied and was thus selected as SLM. Then, factorial screening and Box-Behnken were employed to optimize the technique. The extraction time, concentration of base, sample volume, and percentage of trioctylamine significantly impacted analyte recovery. The optimum values were defined as 120 min, 10 mmol/L of NaOH, 150 µL, and 0%, respectively. Once optimized, validation parameters were 1-100 ng mL-1 as linear range, accuracy ±16.4%, precision >83%, 1 ng mL-1 as limit of quantitation, 0.1-0.75 ng mL-1 as limit of detection, matrix effect <20%, and recovery 20-106%. Additionally, EO purchased from different production batches were tested and achieved acceptable reproducibility. Data were in compliance with requirements set by internationally accepted validation guidelines and the applicability of the technique was proven using authentic samples. SIGNIFICANCE: In this study, the use of an EO provided a solvent-free sample preparation technique suited to extract different classes of drugs of abuse from plasma samples, dismissing the use of hazardous organic solvents. The method also provided excellent sample clean-up, thus being a simple and efficient tool for toxicological applications that is in agreement with the principles of sustainable chemistry.


Assuntos
Espectrometria de Massa com Cromatografia Líquida , Microextração em Fase Líquida , Cromatografia Líquida/métodos , Espectrometria de Massas em Tandem/métodos , Membranas Artificiais , Reprodutibilidade dos Testes , Solventes , Limite de Detecção
11.
J Sep Sci ; 47(5): e2300070, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38466171

RESUMO

Herein, a deep eutectic solvent (DES)-based miniaturized pressurized liquid extraction in combination with DES-based dispersive liquid-liquid microextraction (DLLME) was developed for the extraction of organophosphorus pesticides (parathion-methyl, triazophos, parathion, diazinon, and phoxim) from egg powder samples prior to their analysis by a high-performance liquid chromatography-diode array detector. In this work, first, the analytes' extraction was done by a pressurized liquid phase extraction for effective extraction of the analytes from the solid matrix, and then they were concentrated on a DLLME for more concentration of the analytes to reach low limits of detections. The use of DESs was done in both steps to omit the use of toxic organic solvents. Satisfactory results including high extraction recoveries (74-90%), great repeatability (relative standard deviations equal or less than 4.3% and 5.3% for intra- and inter-day precisions), and low limits of detection (0.11-0.29 ng/g) and quantification (0.38-0.98 ng/g) were attained under the optimum conditions. Lastly, the suggested approach was utilized for the determination of the studied pesticides in various egg powder samples marketed in Tabriz, Iran.


Assuntos
Microextração em Fase Líquida , Paration , Resíduos de Praguicidas , Praguicidas , Compostos Organofosforados , Cromatografia Líquida de Alta Pressão , Solventes Eutéticos Profundos , Pós
12.
Chemosphere ; 354: 141706, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38484993

RESUMO

Aliphatic aldehydes are a class of organic compounds containing aldehyde groups, which are widespread, and closely related to people's daily life and health. In this work, a series of terpenes based hydrophobic deep eutectic solvents were designed and synthesized using hexafluoroisopropanol as hydrogen bond donor and menthol/thymol as hydrogen bond acceptor. Then they are used as extraction solvent in dispersive liquid-liquid microextraction for extracting and determining seven aliphatic aldehydes from drinking water and alcoholic beverage combined with high performance liquid chromatography-ultraviolet. Due to the fact that these hydrophobic deep eutectic solvents are liquid at the room temperature, a density greater than that of water, a lower viscosity (≤26.10 mPa s, 25 °C), after extraction and centrifugation, the microvolume DES-rich phase in the bottom is convenient for collection and direct analysis without further dissolution or dilution with organic solvents. Some factors affecting the extraction recovery were optimized by one-variable-at-a-time and response surface methodology. Under the optimal conditions, the enrichment factors for the seven aliphatic aldehydes were 48-56. The method had good performance: linear ranges of 1.0-200, 0.5-200, 0.2-200, 0.4-400, 1.0-400, 0.4-400 and 0.4-400 µg L-1 for seven aliphatic aldehydes (r2 ≥ 0.9949), limits of detection of 0.1-0.5 µg L-1, intra-day and inter-day precisions <4.9%. The recoveries of seven aliphatic aldehydes ranged from 76.0 to 119.0%. The proposed dispersive liquid-liquid microextraction method is simple, rapid, highly efficient, and green, which effectively reduces the amount of toxic chemical reagents used and their impact on the environment. Rapid and efficient detection of aliphatic aldehydes helps ensure a healthy diet and has great application prospects in food safety analysis.


Assuntos
Água Potável , Microextração em Fase Líquida , Humanos , Terpenos , Solventes Eutéticos Profundos , Microextração em Fase Líquida/métodos , Aldeídos , Limite de Detecção , Solventes/química , Cromatografia Líquida de Alta Pressão/métodos , Bebidas Alcoólicas
13.
Food Chem ; 447: 139024, 2024 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-38493687

RESUMO

This manuscript describes the development of a novel liquid phase microextraction (LPME) method for the extraction and determination of Zn (II), Fe (II), Pb (II), and Cd (II) in various infant/baby food and supplements products. The method is based on vortex-assisted extraction combined with a switchable-hydrophilicity solvent (SHS) sample preparation. The SHS, which undergoes reversible phase changes triggered by pH change, enables selective extraction and easy phase separation. A flame atomic absorption spectroscopy was used in the final determination step. Optimization studies revealed, that the optimal pH of the sample solution (after digestion) during analytes extraction is 5.5. A l-proline is added to the sample (375 mM) to ensure the complexation of the target metal cations. After the complexation step, 750 µL of SHS - a N, N-Dimethylcyclohexylamine along with 0.9 mL of 2 M of acetic acid solution is added (hydrophilicity switch-on stage) and mixed manually to obtain a homogeneous solution. In the last stage, 0.45 mL of 10 M NaOH solution (hydrophilicity switch-off stage) is added to the sample solution and a vortex for 100 s is applied to ensure the effective extraction and separation of the complex containing the analytes. At this stage, a cloudy solution is immediately obtained. Finally, the effective phase separation is obtained at the centrifugation step (4000 rpm for 2 mins). The method limit of detection was as 0.03, 0.009, 0.6, and 0.2 ng/L for Zn (II), Fe (II), Cd (II), and Pb (II) respectively with RSD% below 2.0 %. The analysis of certified reference materials and real samples proved the full applicability of the method for routine analysis, contributing to the field of heavy metal analysis and ensuring the safety of baby products. According to the AGREE methodology, this method can be named as green analytical chemistry method with a score of 0.77.


Assuntos
Cádmio , Microextração em Fase Líquida , Humanos , Solventes/química , Chumbo , Microextração em Fase Líquida/métodos , Alimentos Infantis , Interações Hidrofóbicas e Hidrofílicas , Zinco , Limite de Detecção
14.
Food Chem ; 447: 139036, 2024 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-38518615

RESUMO

In this study, a UV-Vis Spectroscopy-based method was developed for the determination of tin(IV) in epilobium parviflorum tea samples after preconcentration. The preconcentration process was carried out using the liquid-liquid microextraction technique. Before starting the analysis, optimization studies were carried out for the variables likely to affect the experimental results. As a result of the analyzes performed under optimum conditions, the detection limit of our method was calculated as 16.83 µg/L. The percent relative standard deviation value was calculated as 1.25% (n = 8) and linearity was found in the range of 10-1000 µg/L. Recovery experiments were performed on epilobium parviflorum tea samples using the matrix matching method. As a result of the analyzes made on teas belonging to three different brands, recovery results ranging from 92 to 117% were obtained.


Assuntos
Epilobium , Microextração em Fase Líquida , Solventes , Solventes Eutéticos Profundos , Estanho , Microextração em Fase Líquida/métodos , Análise Espectral , Chá , Limite de Detecção
15.
Talanta ; 273: 125847, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38452590

RESUMO

This study investigates the contamination of cow milk with aluminum (Al) and its potential health implications, particularly for children. Cow milk samples were collected from both nonexposed and exposed areas in Sindh, based on the source of livestock drinking water (fresh canals and groundwater). An environmental friendly deep eutectic solvent (DES) was used with ultrasonic-assisted dispersive liquid-liquid microextraction (UDLLµE) to enrich trace amounts of Al in whey milk and water samples. The enriched samples were then analyzed using inductively coupled plasma optical emission spectrometry. Certified reference materials were employed to validate the methodology, and the experimental results exhibited acceptable conformity. The DES-based dispersive liquid-liquid microextraction method was environmental friendly, devoid of acids and oxidizing agents, and used safe and inexpensive components for routine trace metal analysis in diverse samples. The resulting data revealed that Al in whey milk samples was observed in the range of 31-45 %, corresponding to (160-270) µg L-1 and (700-1035) µg L-1 in nonexposed and exposed whole cow milk samples, respectively. Additionally, it was observed that milk boiling in Al utensil for 10-20 min enhanced the Al levels from 3 to 8% of its total contents in milk samples.


Assuntos
Microextração em Fase Líquida , Leite , Criança , Bovinos , Animais , Humanos , Solventes/química , Leite/química , Soro do Leite , Alumínio/análise , Solventes Eutéticos Profundos , Microextração em Fase Líquida/métodos , Limite de Detecção
16.
Artigo em Inglês | MEDLINE | ID: mdl-38527182

RESUMO

Rice is one of the crops cultivated in Malaysia, and it is the main diet for most of the population. In this study, dispersive liquid-liquid micro-extraction (DLLME) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) were used to develop, optimise and validate a reliable, easy-to-use and quick approach to detect aflatoxin B1 (AFB1), aflatoxin B2 (AFB2), aflatoxin G1 (AFG1) and aflatoxin G2 (AFG2). The extraction recoveries in DLLME were enhanced by the addition of 5% salt, utilising chloroform as the extraction solvent and acetonitrile as the dispersive solvent. The DLLME parameters - the extraction solvent volume, salt concentration and dispersive solvent volume were optimised with Box-Behnken design (BBD) and response surface methodology (RSM). Under optimised experimental conditions, excellent linearity was obtained with a limit of detection (LOD) ranging from 0.125 to 0.25 ng g-1, a limit of quantitation (LOQ) ranging from 0.25 to 0.3 ng g-1 and a correlation value (R2) of 0.990. The matrix effects were between -11.1% and 19.9%, and recoveries ranged from 87.4% to 117.3%. The optimised and validated method was used effectively to assess aflatoxins contamination in 20 commercial rice samples collected from local supermarkets in Penang, Malaysia. AFB1 was detected at 0.41-0.43 ng g-1 in two rice samples, below the regulatory limit.


Assuntos
Aflatoxinas , Contaminação de Alimentos , Microextração em Fase Líquida , Oryza , Espectrometria de Massas em Tandem , Oryza/química , Aflatoxinas/análise , Malásia , Contaminação de Alimentos/análise , Cromatografia Líquida , Espectrometria de Massa com Cromatografia Líquida
17.
Artigo em Inglês | MEDLINE | ID: mdl-38547699

RESUMO

In this research, a method known as a hollow fiber-liquid-phase microextraction was employed to extract and concentrate free metoprolol from plasma samples. The extracted analyte was subsequently determined using high-performance liquid chromatography coupled with a diode-array detector. Several parameters, including hollow fiber length, sonication time, extraction temperature, and salt addition, were investigated and optimized to enhance extraction efficiency. After extracting the analyte under optimum conditions from plasma samples, the enrichment factor and extraction recovery were 50 and 86 %, respectively. Moreover, the method exhibited detection and quantification limits of 0.41 and 1.30 ng mL-1, respectively. The analysis of real samples demonstrated satisfactory relative recoveries in the range of 91-99 %.


Assuntos
Microextração em Fase Líquida , Metoprolol , Microextração em Fase Líquida/métodos , Cromatografia Líquida de Alta Pressão/métodos , Cloreto de Sódio , Sonicação
18.
Anal Methods ; 16(11): 1697-1707, 2024 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-38421023

RESUMO

Performant sample preparation is mandatory in any leachable study to clean and preconcentrate analytes within the sample to offer the best possible extraction recovery as well the best precision for any given substance. The aim consists in developing a sample preparation method for hospital pharmacy-prepared drug products such as long-term storage prefilled syringes, vials and IV bags for the screening of leachable compounds. The Quality Control Laboratory of the Pharmacy of the Lausanne University Hospital (Switzerland) has developed a time- and cost-effective, highly sensitive, robust, and fast method using liquid chromatography coupled with high-resolution mass spectrometry (LC-HRMS) for the analysis of 205 plastic additives. An innovative setup, based on postcolumn infusion (PCI) using 2% ammonium hydroxide in methanol was used to boost the signal intensity of the analytes in MS detection. A database for extractable and leachable trace assessment (DELTA) was built to assist in the screening process of 205 plastic packaging-related compounds. The development of the sample preparation was based on 33 plastic additive candidates in different hospital pharmacy compounding solutions, and their extraction recovery rates as well as their relative standard deviation were taken into consideration. In conclusion, the developed DLLME was assigned with ultrasound assistance and triple extraction, which brought about extraction recovery rates between 67% and 92%, a good RSD <10%, and a preconcentration factor of 50×. Therefore, DLLME could be considered suitable for the semiquantitative screening of leachable additives in simple hospital pharmacy-prepared prefilled drug products.


Assuntos
Microextração em Fase Líquida , Serviço de Farmácia Hospitalar , Humanos , Microextração em Fase Líquida/métodos , Metanol , Embalagem de Medicamentos , Manejo de Espécimes
19.
J Chromatogr A ; 1719: 464753, 2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38394784

RESUMO

In this study, MIL-88(Fe) coordinated to carboxymethyl cellulose fibers was successfully synthesized, characterized, and utilized as a nanocomposite for the dispersive solid phase microextraction of butachlor and acetochlor. These analytes served as representative analytes for acetanilide herbicides (AHs) present in real samples. Effective parameters on the extraction efficiency were investigated to maximize the analytical performance of the developed method. Under optimized conditions, which encompassed sorbent amount of 12 mg, solution pH of 7.0, 4.0 min of the vortex time, 3.0 min of the extraction time, chloroform as desorption agent and no salt addition, the developed method exhibited remarkable figures of merit, such as high linearity (R2> 0.99), low limits of detection of 0.90 ng mL-1, substantial preconcentration factors (between 213 and 228), relative recoveries in the range of 90.8% to 109%, and good repeatability with relative standard deviations equal or below 7.2%. After validation, the developed method was applied to detect AHs in various cereal and agricultural soil samples.


Assuntos
Herbicidas , Microextração em Fase Líquida , Nanocompostos , Microextração em Fase Sólida/métodos , Herbicidas/análise , Carboximetilcelulose Sódica , Grão Comestível/química , Solo , Acetanilidas/química , Extração em Fase Sólida/métodos , Microextração em Fase Líquida/métodos
20.
Artigo em Inglês | MEDLINE | ID: mdl-38417274

RESUMO

Clomipramine (CLP) is a tricyclic antidepressant drug, and its determination in biological samples is of high importance in clinical and forensic evaluations to assure appropriate drug concentrations. In the present study, benzoic acid was employed as a pH-switchable hydrophilicity solvent (SHS) for the microextraction of CLP from authentic human urine samples prior to its determination by high performance liquid chromatography-ultraviolet detection (HPLC-UV). The microextraction protocol was based on the phase transition of the SHS through pH alteration that resulted in its rapid dispersion and simultaneous phase separation. The obtained solid was collected in a syringe filter, dissolved in methanol, and analyzed. The main parameters that affected the efficiency of the microextraction procedure were studied and optimized to ensure high extraction efficiency for CLP and the analytical method was validated. Under optimum conditions, good linearity was observed between 0.05 and 5.0 µg mL-1. The limit of detection and limit of quantification were found to be 0.015 and 0.05 µg mL-1, respectively. The RSD values for intra-day repeatability and inter-day precision were 2.4-8.9 % and 1.7-9.1 %, respectively. The relative recovery values were within 90.0 and 110.0 % in all cases, demonstrating good method accuracy. The proposed SHS microextraction showed cost-efficiency, handling simplicity, and rapidity resulting in enhanced sample throughput. Moreover, the proposed method exhibited a green character and good applicability based on its evaluation by Green Analytical Procedure Index and Blue Applicability Grade Index.


Assuntos
Clomipramina , Microextração em Fase Líquida , Humanos , Clomipramina/urina , Solventes , Microextração em Fase Líquida/métodos , Interações Hidrofóbicas e Hidrofílicas , Cromatografia Líquida de Alta Pressão , Concentração de Íons de Hidrogênio , Limite de Detecção